Télécharger Imprimer la page

Clean Air Optima CA-607B Mode D'emploi page 7

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
Auto Mode:
Depending on the temperature, the humidifier sets the optimum humidity
Temperature of the air, degrees Celsius
19 and lower
20-21
22-23
24-25
26-27
28-29
a. The optimal humidity levels with different temperatures are taken from the data base of the
device.
b. The device works at maximum power until the optimal humidity is achieved.
c. If the optimal humidity is achieved, then the humidification will stop.
d. The device checks the accordance of the temperature level and the humidity level every 10
minutes.
Baby Mode:
When the Baby Mode is activated, the device turns on the function of warm mist & UV-Light
and starts to achieve 55% humidity at maximum power. If the 55% humidity is achieved, then
the humidification will stop. The device checks the humidity level every 10 minutes.
Health Mode:
When the Health Mode is activated, the device turns on the function of warm mist & UV-Light,
it will calculates the optimal humidity and starts to achieve it at maximum power.
The optimal humidity in Health Mode is calculated as in the Auto Mode, the only difference is
that the device add 5% to the result.
Example:
Optimal humidity in Auto Mode = 50%, Optimal humidity in Health Mode = 50 + 5 = 55%
When the optimal humidity level is achieved, then the humidification will stop.
The device checks the accordance of the temperature level and the humidity level every 15
minutes.
Humidity %
65
60
55
50
45
40
7

Publicité

loading