Lighting Procedure - habitat et jardin Relax 2 Mode D'emploi

Parasol chauffant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LIGHTING PROCEDURE

1. Turn the control knob OFF. Slowly open
the gas cylinder valve.
2. Push in and turn
control knob
anti-clockwise to
IGNITE.
3. Keep control knob depressed for up to 30
seconds until pilot is lit.
If pilot does not light, turn control knob to
OFF and wait 2
minutes between
ignition attempts for
gas to dissipate.
Failure to do this
may result in flame
roll out beyond the
emitter grid.
Note: it is possible
to light the appliance
using a long match, by lighting the burner
through the ignition hole provided.
4. When the pilot is lit keep knob pressed
for up to 20 seconds to heat the thermo-
couple flame sensor, then release it (first
ignition generally takes more time, because
the gas circuit is full of air).
5. If the pilot does not stay lit, repeat steps
2 - 4.
6. Turn knob to LOW position.
7. Adjust the heat input by turning the knob
from the LOW position, to the HIGH posi-
tion, as required.
8. After lighting, turn knob from LOW to
HIGH, position and back, to check flame
stability.
9. In case of accidental break down of the
flame (due to wind or other reasons), a
Flame Safely Device (FSD) will automati-
cally shut-off gas supply within 90 seconds.
These lighting instructions must be
followed. An unsafe condition can
occur if they are not followed correctly.
Flame Characteristic
The flame pattern at the emitter screen
should be visually checked whenever heater
is operated.
If black soot is accumulating on the emitter
grid or reflector, the heater should be turned
off immediately. The heater should not be
operated again until the unit is serviced and
or repaired.
10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1351 86826

Table des Matières