Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need a PAR-36 6V/35W terminal screw lamp.
Procedure:
Step 1: Remove the color filter frame from the device (see drawing below).
Step 2: Please remove the fixation ring by pressing it together.
Step 3: If replacing the lamp, remove the old lamp from the housing and loosen the screws and wires.
Step 4: Loosen the screws on the new PAR-36 6V/35W terminal screw lamp with an appropriate
screwdriver.
Step 5: Connect the wires with the lamp using an appropriate screwdriver and tighten the screws.
Step 6: Insert the lamp in the housing and fix it with the fixation ring.
Step 7: Replace the color filter frame.
Installing/Replacing the color filter frame
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device without color filter frame!
16/35