GENERAL MACHINE DESCRIPTION AND PURPOSE OF THE PRODUCT
Ergonomic, modular and height adjustable motorized workbench. The workbench is designed for professional
use in the industrial working environments, mostly in light assembly workspaces. The machine components include
actuators, control box and desk panel.
OPERATING CONDITIONS
The table is designed to be in dry indoor conditions. It must not be exposed to moisture, corrosives, dust, etc.
(IP20). Operating temperature is from 5°C to 40°C. The workbench cannot be used in EX / ATEX environments.
FIRST USE
Before using the workbench for the first time, reset the table: Run the table to the lowest position. Press down again
and hold for a few seconds, until the table resets.
VOLTAGE
The table can be connected to an ungrounded network of 230 V/50 Hz or 115 V/60 Hz.
OPERATION
The maximum load capacity is marked on the table frame. The load should be divided evenly on the table top.
The table can be raised by pressing the up-arrow button on the desk panel, and lowered by pressing the
down-arrow button. The duty cycle of the motor (ED%) is 10%.
NOISE LEVEL
The noise level is under 45 dB(A) DS/EN ISO 3746.
MAINTENANCE
The motors and control unit of the table do not require maintenance. Do not open motor and control unit covers.
Screw couplings under stress should be checked at regular intervals. Dust the top of the product regularly with a
duster or damp cloth. Always use the recommended cleaning equipment and materials in ESD areas. Since dirt on
ESD products can reduce their ESD capabilities, remove dirt from the wheels regularly.
LOADING THE ADJUSTABLE TABLE
Loading capacity 500 kg with evenly loaded, nominal load 400 kg
WARNINGS
When driving the workbench downwards, ensure that no humans or objects are in danger to be crushed. It is
prohibited to use the workbench as a man lifter. Disconnect the machine from electrical network before repairing
work. Mounting of the workstation to the floor is prohibited. For all requests for spare parts, the request must be
made to the local office.