Steps For Installation
The following pages provide the necessary information for proper installation of the oven and are arranged as follows:
• Technical Data
• Installation Cutout Dimensions, Required Clearances and
• Mounting instructions for:
- Under counter Installation, Single Oven
- Wall Installation, Single Oven
• Electrical Connections for 3-wire or 4-wire Branch Circuit.
• Final Checklist
TECHNICAL DATA
For cutout dimensions see following section titled:
Preparing location
SINGLE OVEN
F1SP30*3
Installation Notes
1. Do not slide oven across floor. Damage to floor covering or
floor could result.
2. The oven support surface must be a minimum 3/4" (2cm)
thick plywood platform.
For single ovens, it must support 202 pounds.
The platform must be solid, level and flush with the bottom
of the cabinet cut out.
3. Use extreme caution when moving or installing the oven.
It is very heavy. DO NOT LIFT THE OVEN BY THE DOOR
HANDLE, remove the door for easier handling and
installing. See REMOVING THE DOOR in the maintenance
section of the Operating Instructions.
4. Be very careful when moving or installing the oven to avoid
damage to the oven frame or damage to the cabinets.
5. Be sure to level the oven. An oven that is not level may
provide poor or inconsistent baking results.
6. Be careful when placing oven. DO NOT pinch the conduit
between the oven back.
WARNING
Before installing or removing, turn power OFF at the service
panel. Lock service panel to prevent power from being
turned ON accidentally.
Securely fasten oven to cabinet using the screws provided.
Failure to do so could result in oven moving or tipping during
use and causing damage to the oven or cabinets or personal
injury.
Know how to disconnect the power to the oven at the circuit
breaker or fuse box in case of an emergency.
Electrical Ratings and Maximum Connected Load
@ 120V/240V 60Hz
Amperes
kW
16.2
3.80
CAUTION
Unit is heavy and requires at least two people or proper
equipment to move.
CAUTION
Do not remodel the oven.
Ltr.
DIMENSION
A
Cutout Width
Cutout Depth
B
C
Cutout Height
D
Oven Position (distance from floor)
E
Minimum Spacing
@ 120V/208V 60Hz
Amperes
kW
17.9
3.65
SINGLE
28"
(71 cm)
24"
(61 cm)
23"
(58,5 cm)
34"
(86,5 cm)
1/2"
(1,3 cm) min
EN