Procedure
Check heater
Check gas supply line
Clean exterior of heater
Clean motor and fan
Check gas supply pressure
Check electrical connections
Check and test burner
Check thermostats
Clean interior of heater
Inspect
and
clean
combustion
chamber
6.1. CHECKING THE HEATER AND THE GAS SUPPLY LINE
Perform the following checks:
• Make sure the heater is not installed where there may be a risk of
fire or explosion
• Make sure that flammable materials are kept a safe distance away
• If you smell:
• Open the windows immediately
• Do not touch electrical switches
• Close the gas stopcock
• Find and repair the source of the gas leak
• Do not use the heater if any removed panels have not been
remounted
• Make sure the room to be heated is sufficiently ventilated
• Make sure that the air intake and outlet are completely
unobstructed
• Make sure that the heater is not covered by any sheets or covers;
• Check that the heater is in a fixed and stable position;
• Make sure the heater is constantly monitored during operation and
checked before being started
6.2 CLEANING THE EXTERIOR OF THE HEATER
To ensure efficient operation, clean the following parts:
• Burner:
• Remove all external dirt and debris
• Make sure the air inlet is not obstructed.
• Pipes, connectors and joints:
• Clean with a cloth.
• External body:
• Clean with a cloth.
• Air inlet/outlet:
• Remove all dirt and debris
• Make sure the air inlet is not obstructed.
6.3 Cleaning the motor and the fan
Clean the fan blades and the motor as follows:
• Remove the fan group fixing screws and then remove the fan
group.
• Clean the motor with compressed air.
• Clean the fan blades with a hard brush.
L-L 229.00-BM
Periodic maintenance
X
X
X
X
X
X
X
X
X
X
EN
• Reinstall the fan group.
6.4 CHECKING THE ELECTRICAL CONNECTIONS
After detaching the power cable, check all electrical connections as
follows:
• Make sure that all connections are complete and tight.
• If there are traces of dirt or corrosion, clean or replace the
connections if necessary.
• Replace any damaged wires or connectors if necessary.
6.5 CHECKING AND TESTING THE BURNER
To reach the burner:
• Remove the burner fixing screw.
• Remove the burner and follow the checking and cleaning
instructions in the burner manual.
• Reinstall the burner.
• Run the procedures described in paragraphs 4.7 and 4.8 to
measure combustion parameters and check that combustion is
stable and clean.
6.6 CHECKING THE THERMOSTATS
Inspect the thermostat burner as follows:
• Remove any air outlet connection ducts
• Find the thermostats fixed to the internal panel of the space
heater.
• Clean with a dry cloth, taking care not to cut or bend the capillary
tube.
6.7 CLEANING THE INTERIOR OF THE HEATER
For thorough cleaning, the heater can be cleaned and washed inside
and outside with water. It is however necessary to ensure that:
• the electrical cable is disconnected and unplugged from the
socket
• completely close all access panels
• do not use water jets at a pressure exceeding 70 bar at a distance
less than 30 cm
• completely dry all parts before reconnecting the electrical cable.
6.8 CLEANING THE COMBUSTION CHAMBER
To maintain the burner's high efficiency and prolong its life, the
procedure described in this paragraph must be done at least once at
the end of the work season or more frequently if there is an
excessive build-up of soot. Excessive soot may be caused by poor
chimney draught, poor fuel quality, poor regulation of the burner, or
more or less frequent alternation of burner starts and stops.
Pay attention during operation: pulsations at start may be due to
excessive amounts of soot..
To access the heat exchanger (1), take off the rear panel (3), remove
the smoke box inspection panel (2), and then remove baffle plates
(7).
To access the combustion chamber (4) remove the burner (5).
Clean with compressed air or, if necessary, with a metal brush to
remove any deposited soot and combustion residues.
Warning
After any technical work, always check that the heater
works correctly.
7. TROUBLESHOOTING
In the event of serious anomalies, various safety devices are able to
block the machine's operation and signal the same:
• on the electrical panel
35 / 72