Relay output (12 V) - Auxiliary heat
This output provides 12 Vdc through a relay. It offers control over a heat supply stage in
situations when the unit is unable to reach the setpoint temperature desired by the user. By
default it is disabled.
Diagnostic LEDs
Transmission of data to the indoor unit
Reception of data from the indoor unit
Meaning
Connecting to a Wi-Fi network
Connected to a Wi-Fi network
Connected to the server
Not configured
Cloud Communications
Microprocessor activity
Power supply
Blinking
Green
Steady
Steady
Blue
Off
-
Blinking
Red
Blinking
Green
Steady
Red
Blinking
Red
Blinking
Green
EN