Lid with
Locking
Ring
and
Seal
Blue
Pressure
Test
O-ring
(Note: Discard
after pressure
test is complete.)
Pump
Debris
Trap
Basket
(Inside
Pump)
Figure 14. Exploded View with Blue Pressure Test
O-ring (VSSHP Pump Models Only)
3.7.1
Replace Blue O-ring Before Pressure
Testing, if necessary
1.
Make sure that the pump is turned off.
2.
Make sure that the switch to the circuit breaker that
powers the pump motor is turned off.
ELECTRICAL SHOCK HAZARD
Due to the potential risk of fire, electric shock, or injuries to
persons, Jandy
Pumps must be installed in accordance
®
with the National Electrical Code
and safety codes, and the Occupational Safety and
Health Act (OSHA). Copies of the NEC may be ordered
from the National Protection Association, 1 Batterymarch
Park, Quincy, MA, 02169, or from your local government
inspection agency.
In Canada, Jandy Pumps must be installed in accordance
with the Canadian Electrical Code (CEC).
ELECTRICAL SHOCK HAZARD
Turn off the pump and the main breaker in the pump
electrical circuit before starting the procedure. Failure to
comply may cause a shock hazard, resulting in severe
personal injury or death.
3.
Make sure all necessary isolation valves are closed
to prevent pool water from reaching the pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
markings align with the ports.
5.
Carefully remove the lid with locking ring.
Upside Down View of
Groove where
Seal is Seated
Figure 15. Placement of Blue Pressure Test O-ring
|
Installation & Operation Manual
WARNING
(NEC
), all local electrical
®
®
WARNING
Bottom of Lid
Step where
O-ring is Seated
ENGLISH
3.7.2
Replace Blue O-ring
1.
Turn the lid with locking ring upside down.
2.
Place the blue o-ring on the step located ¼" from
the bottom of the lid. See Figure 15.
3.
Make sure that the o-ring is properly seated.
4.
Install the lid, making sure that the blue o-ring sits
in the housing without "binding" or "rolling" off.
5.
Follow the markings on the locking ring, align
'START' markings with the ports and turn
clockwise until 'LOCKED' markings align. Do not
tighten past the 'LOCKED' marking.
Section 4. Operation
4.1
Start-up
Never run the pump without water. Running the pump "dry"
for any length of time can cause severe damage to both the
pump and motor and will void the warranty.
If this is a new pool installation, make sure all piping
is clear of construction debris and has been properly
pressure tested. The filter should be checked for
proper installation, verifying that all connections and
clamps are secure according to the manufacturer's
recommendations.
To avoid risk of property damage, personal injury or death,
verify that all power is turned off before starting these steps.
4.1.1
Pump Below Water Level
1.
Ensure the pump lid is secure by verifying the
"locked" indicators are aligned with the pump's
ports. Hand tighten only, do not use tools. Make
sure valves are open and the pump unions are tight.
2.
Open any isolation valves that may be in place
between the pump and the pool's main drain(s) and
skimmer(s).
3.
Open the air relief valve on the filter. This will
allow air to begin to escape the system and fill the
pump with water for priming.
4.
Restore power to the pump and start the pump.
5.
When water starts to come out of the air relief valve
on the filter, close the air relief valve.
6.
Inspect system for any leaks.
4.1.2
Pump Above Water Level
1.
Open the air relief valve on the filter.
2.
Remove the pump lid and fill the basket with water.
3.
Prior to replacing the lid, check for debris around
the lid o-ring seat. Debris around the lid o-ring seat
may cause an air leak and will make it difficult for
the pump to prime.
Page 17