2 - Make sure screw on steel cable clamp is tightened securely using force (pict. 13).
3 - Make sure lever presses the central limit switch. If it does not, loosen locknut that locks
the adjuster and regulate the adjuster until the castor reaches the proper position (pict.
14).
4 - Unscrew fastening screws of lower cover and remove it (fig. 2 - part. 2).
5 - Marks position (S) on upper side of fastening slot on the side of the aluminum bar (pict.
2 - part. 3).
6 - Position TOUCH Wi-Fi on the wall and mark the position corresponding to the reference
marked previously. In cases of vertical assembly, keep a minimum distance from the
ground of 30 mm and aim the device as shown in pict. 2 - part. 2.
7 - Perforate strip support surface about 7 mm under reference mark and fasten retention
spring with appropriate elements: screws for metal or screws and anchor bolts for
masonry (pict. 2 - part. 4).
8 - Position TOUCH Wi-Fi on retention spring and hook it by pulling it downward.
9 - Mark fastening holes on wall in correspondence to -C- and -D- (pict. 2 - part 1 and 2).
10 - Remove device and drill fastening holes marked previously.
11 - Hook device to spring again and tighten screws.
12 - Insert lower cover into notch and fasten with screws (pict. 15).
13 - Insert upper cover and fasten with screws.
14 - Check functioning of TOUCH Wi-Fi as described under the paragraph of "CHECK PROPER
FUNCTIONING".
9
11
Regulation check nut
Position the roller on central micro-switch pin
Position the roller on central micro-switch pin
13
17
Insertion
G
B
10
12
14
15