Four outputs interface fenced from the optocoupler input. When injected on any input voltage between 3 and 24 V. DC
and while this remains applied, the output is activated. Allows Control TTL or CMOS signals.
Incorporates protection against reverse polarity, LED indicators and terminals work.
POWER: From 24 VDC., We recommend using power Cebek FE-115/FE-16.
Install a fuse and a switch. Both are necessary for the protection of the module for your own safety, as reflected in the
CE standard.
Respecte negative and positive wiring
OPERATION: It has four inputs, each independent from the other and their corresponding outputs. In each of these
entries, by injecting a voltage signal, the output is activated, connecting to the relay, and will continue in that state while
input this signal remains applied. The voltage applied to the inputs may
be different from each other, but they can never be less than 3 V. not more than 24 V. DC
INSTALLATION: Make wiring connection of their control signals to the inputs. Note the polarity identification of these.
The wiring should be as short as possible, you must use shielded cable.
Quatre sorties Interface clôturé à partir de l'entrée opto-coupleur. Lorsqu'elle est injectée sur une tension d'entrée
comprise entre 3 et 24 V. DC et tout cela reste appliquée, la sortie est activée.
Permet un contrôle TTL ou CMOS signaux. Intègre une protection contre les inversions de polarité, les indicateurs LED
et terminaux travail.
1
4 OUTPUTS BY RELAY INTERFACE
4 Interface de sortie Optocoupleur Relais
Interface 4 salidas optocopladas a relé
Interface 4 sortides optocoblades a relé
www.cebek.com
-
T-31
TECNHICAL CHARACTERISTICAS
Voltage : 24 V. DC
Low energy : 0.2 mA.
Maximum consumption : 120 mA.
Current Min. Entry : 10 mA
Low voltage. Input : 3 V. DC
Max. Input : 24 V. DC
Max. Relay output : 3 A.
Reverse polarity protection : Yes.
Sizes : 132x72x30 mm.
Weight : 138 g.
Din rail : C-7570
sat@fadisel.com