1 output interface fenced from the optocoupler input. When injected on any input voltage between 3 and 24 V. DC and
while this remains applied, the output is activated. Allows Control TTL or CMOS signals.
Incorporates protection against reverse polarity, LED indicators and terminals work.
POWER: From 100 – 240 VAC 50/60 Hz
Install a fuse and a switch. Both are necessary for the protection of the module for your own safety, as reflected in the
CE standard.
Respecte negative and positive wiring
OPERATION: It has an entrance and an output. In each of these inputs, when a voltage signal is injected, the
corresponding output will be activated, connecting to the relay, and will continue in that state as long as said signal is
applied to the input. The voltage applicable to the inputs may be different from each other, but they may never be less
than 3 V. or greater than 24 V. DC
INSTALLATION: Make wiring connection of their control signals to the inputs. Note the polarity identification of these.
The wiring should be as short as possible, you must use shielded cable.
1 sortie Interface clôturé à partir de l'entrée opto-coupleur. Lorsqu'elle est injectée sur une tension d'entrée comprise
entre 3 et 24 V. DC et tout cela reste appliquée, la sortie est activée.
Permet un contrôle TTL ou CMOS signaux. Intègre une protection contre les inversions de polarité, les indicateurs LED
et terminaux travail.
1
1 OUTPUT BY RELAY INTERFACE
1 Interface de sortie Optocoupleur Relais
Interface 1 salida optocoplada a relé
Interface 1 sortida optocoplada a relé
www.cebek.com
-
T-44
TECNHICAL CHARACTERISTICAS
Voltage : 100-240VAC
Low energy : 1W.
Maximum consumption : 3W
Current Min. Entry : 10 mA
Low voltage. Input : 3 V. DC
Max. Input : 24 V. DC
Max. Relay output : 3 A.
Sizes : 64 X 72 X 30 mm.
Weight : 78 g.
Din rail : C-7564
sat@fadisel.com