Machine specification
Technical info.
TJEP no.
Weight
Size (L × B × H )
Wraps per tie
Workpiece thickness
Ties per charge
Battery
Charger
Charging time
Wire specification
Model
Diameter
Length
Material
Ties per coil
2 wraps
3 wraps
Applications
Tying of re-bars used for: prefab. concrete elements,
on-site concrete constructions, floors and walls.
Tying of floor heating pipes.
Safety features
To increase safety when tying, the re-bar binder is
equipped with safety features.
WARNING! Before use, make sure that the
!
device works as intended. Otherwise, do not
use the re-bar binder.
Trigger lock
The re-bar binder is equipped with a trigger lock.
Lock the trigger and remove the battery when the
re-bar binder is not in use.
Trigger
Trigger lock
14
TJEP EP 40
124000
2.6 kg
297 × 1 09 × 3 00 mm
2 or 3
12 - 40 mm
+4.500 (3 wraps)
18V 4,0Ah Li-ion
Use only approved battery charger Li18C
(TJEP no. 124201).
Full charge = 90 min.
Box: 50 coils (TJEP no. 124151)
0.8 mm
approx. 100 m
Galv.
TJEP EP 40
approx. 160
approx. 120
When you start tying, release the trigger lock by
pushing the lock left and upwards.
Curl guide
If you pull the trigger while the curl guide is open, the
re-bar binder will make a warning sound and refuse
to tie. To start tying, release the trigger and make
sure that the curl guide is closed.
Curl guide
Battery
Durability of the battery
If the battery is fully charged, but the operating time
is significantly reduced, the battery is defective and
must be replaced. If the battery temperature is low
(10°C or lower) the charging time will be prolonged.
WARNING! Do not use defective batteries.
!
The re-bar binder will not work properly.