4. Undo screws on the base element (3 pcs) and mount the struts
- first remove the screw near the fiber management frame.
mafm_0516
Screw near the frame
5. Open and remove all sealing segments as described in the installation instructions S46998-A19-P522.
6. Detach the fiber management structure from the end cap and remove the end cap.
7. Insert new end cap and install in the reverse sequence (as described in the installation instructions
S46998-A19-P522.
mafm_0457_1
mafm_0518
mafm_0525
Struts
mafm_0517
Screw on the base element
mafm_0519
mafm_0526