PERLICK RESIDENTIAL INSTALLATION MANUAL
DIGITAL TEMPERATURE CONTROL
C-Series Models
Figure 2. nEW 961 Digital Temperature Controller
Perlick C-Series units come standard with digital control.
Programming Button Definitions:
STAND-BY (ESC)
Press and release
• Returns to the previous
menu level
• Confirms parameter value
Press for at least 5 sec.
• Activates the Standby
function (off ) (When
outside the menus)
UP
Press and release
• Scroll menu items
• Increases values
Press for at least 5 sec.
• Activates the Manual
Defrost function
To Change Setpoint Temperature
1. Press
. "SP" will be displayed. Press
current setpoint temperature.
2. Press
and
to modify it and
change.
On/Off
To turn the unit off, press and hold
"OF" will be displayed. To turn the unit on again, press and hold
for at least 5 seconds.
NOTE: Dependent on the model and configuration, the controllers
have been programmed to only allow a temperature adjustment
within a specified range. See the chart below for the specified range
allowed for your unit.
6
perlick.com
SET (ENTER)
Press and release
• Opens Machine Status menu
and displays alarms (if active)
Press for at least 5 sec.
• Opens Programming menu
• Confirm commands
DOWN
Press and release
• Scroll menu items
• Decreases values
Press for at least 5 sec.
• Function can be configured
by the user
again to display
or
to save the
for at least 5 seconds.
C-Series Models
Model
HC24R
HA24BB
HA24WB
LED Functions
The following table describes LED Funtions
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
Off: otherwise
Evaporator LED
Permanently on: fans active
Off: otherwise
Aux LED
Permanently on: Aux output
active
Off: otherwise
NOTE: When switched on, the device performs a Lamp Test; the
display and LEDs will flash for several seconds to check that they all
function correctly.

DIAL TEMPERATURE CONTROL

ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller found
on page 5)
3
2
1
Figure 3. Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial temperature
control. The control is located at the top rear panel of the
cabinet. Approximate temperature ranges are as follows:
ADA-Compliant Series
Model
HA24RB
HA24BB
HA24WB
Temp Range
33° - 42° F
33° - 48° F
45° - 65° F
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
Off: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a
locked start-up
Off: otherwise
°C LED
Permanently on: display the
temperature
Off: otherwise
4
5
6
COLD
OFF
Temp Range
33° - 42° F
35° - 48° F
45° - 65° F

Publicité