NOTE: Dependent on the model and configuration, the controllers
have been programmed to only allow a temperature adjustment
within a specified range. See the chart below for the specified range
allowed for your unit.
Signature Series – Dual-Zone Units
Model
HP24D
Dual-Zone Temperature Scale
To change F to C, press and hold the down arrow for 3 seconds.
Signature Series 15", 24" Single-Zone and Sottile, and 48" ,
ADA Freezer Control Instructions
To Set Target Temperature
Press and release the SET button. Display will show the current
temperature setpoint.
To Change Setpoint Temperature
1. Press and hold the SET button until the display shows the
current setpoint temperature with the "F" flashing.
2. Use the UP and DOWN arrow button to scroll to the desired
temperature.
To Start A Manual Defrost (Freezer Models Only)
Press the DEFROST button (melting snowflake)
To Set Maximum Stored Temperature
Press the UP arrow button to see the maximum stored
temperature. To reset the maximum stored temperature, while
displayed, press and hold the SET button until 'rst' flashes in the
display.
To Set Minimum Stored Temperature
Press the DOWN arrow button to see the minimum stored
temperature. To reset the minimum stored temperature, while
displayed, press and hold the SET button until 'rst' flashes in the
display.
On/Off
Press the ON/OFF button to turn the unit on or off.
Key Combinations:
Press the UP and DOWN arrow
+
buttons to lock and unlock the
keyboard
Press the SET and DOWN arrow
+
buttons simultaneously to enter
programming mode.
Press the SET and UP arrow buttons
+
simultaneously to return to room
temperature display.
Range (F)
Upper 51° - 65° / Lower 45° - 60°
PERLICK RESIDENTIAL INSTALLATION MANUAL
NOTE: Dependent on the model and configuration, the controllers
have been programmed to only allow a temperature adjustment
within a specified range. See the chart below for the specified range
allowed for your unit.
Signature Series – HP15 Models
Model
Min Temp Set
HP15R
HP15B
HP15W
HP15T
Signature Series – HP24 Models
Model
Min Temp Set
HP24R
HP24F
HP24B
HP24W
HP24T
Signature Series – HP48 Models
Model
Min Temp Set
HP48WO
HP48WW
Signature Series Sottile
Model
Min Temp Set
HH24RS
HH24BS
HH24WS
ADA-Compliant Series
Model
Min Temp Set
HA24FB
LED Functions
The following table describes LED functions
LED
Mode
ON
Flashing
ON
ON
Flashing
Max Temp Set
33° F
42° F
33° F
48° F
45° F
65° F
33° F
42° F
Max Temp Set
33° F
42° F
-10° F
10° F
33° F
48° F
45° F
65° F
33° F
42° F
Max Temp Set
40° F
65° F
40° F
65° F
Max Temp Set
33°
42°
33°
48°
45°
65°
Max Temp Set
-10°
10
Function
Compressor is on
Anti-short cycle
delay is on
Defrost is on
Alarm is on
You are in the process of
programming the unit