Table of Parameters and Factory Settings
Parameter
Function
Set
Setpoint
PAS
Password
E1
Lowest set
point limit
E2
Higher set
point limit
E3
Temp.
Hysteresis
E40
Turning On
delay time
E41
Comp. start
delay time
E5
Offset on Air
Temperature
E6
Offset on
Product
Temp.
Set Range
Default
72.0°F
72.0°F
22.5°C
22.5°C
00~99
68.0°F
68.0°F / 20.0°C
20.0°C
77.0°F
77.0°F / 25.0°C
25.0°C
0.1~20.0°C /
2.0°C / 3.6°F
0.2~36.0°F
00 ~10 min.
3 min.
00 ~10 min.
3 min.
1.8°F/ 1.0°C
1.8°F/ 1.0°C
-10.0~10.0°C / -
0.0°C / 32°F
18.0~18.0°F
Parameter
C3H
Temp. Alarm
15
C3L
C4
C5
Temp. Alarm
C6
Temp. Alarm
C7
C8
C9
C10
12
Function
Set Range
Product
77.0°F
Temp. High
25.0°C
Product
68.0°F
Temp. Low
20.0°C
Temp. Alarm
Hysteresis
0.1~20.0°C /
Alarm
1.8~36.0°F
Start-up
00~99 min
delay
00~99 min
Delay
Power Off
00=do not alarm /
relay Alarm
01= alarm
Alarm relay
00=open /
close after,
01=close
muffle alarm
relay switch
Restart time
00=do not start /
after buzzer
01 ~30 min=restart
mute
time
Comp.
01~99 min
Force stop
time
Default
77.0°F
25.0°°C
68.0°F
20.0°C
0.1°C /
0.18°F
60 min
0 min
01
00
10 min
99 min