1.
Filling hose with monometer and valve
2.
Electrical motor (or internal combustion engine)
3.
Tubular frame
4.
Cooling fan
Compressor Model
Operating pressure
Air output
Safety valve max. pressure
Pumping Group
Number of stages
Intermediate pressure 1
stage
st
Intermediate pressure 2
stage
nd
Intermediate pressure 3
stage
rd
Intermediate pressure 4
stage
th
Oil sump capacity
Oil Type
Ambient temperature operating limits
Max. permitted inclination
Max. air humidity
Max. altitude above sea level
Electrical motor
Type of current
Electrical motor power
Protection
Absorption
Internal Combustion Engine
Start up
Cylinder capacity
Internal combustion engine power
ATLANTIC 100 - Rev.00/19
ATLANTIC P100-G100
5.
6.
7.
8.
9. Vibration damping feet
4. TECHNICAL DATA
PN 200
100 L/min. (± 5%)
225 Bar
ALUCHEM ALUSYNT 750 PLUS
-5°C Min. +45°C Max. (+25°F Min. +113°F Max.)
Single phase
230 Volt / 50–60 Hz
3.0 Hp 2 poles
IP 54
17 A
ROBIN EX17 6.0 Hp 4 STROKE
4.4 Kw-6.00 HP / 3900 r.p.m.
Cod. AT200-005
Air conveyor
Condensate release valves
Maximum pressure safety valve
Intake filter
ATLANTIC 100
PN 300
100 L/min. (± 5%)
330 Bar
ATLANTIC 100
4
2.5 Bar
15 Bar
55 - 65 Bar
225 - 330 Bar
0.350 Litres
10°
80%
2000 m a.s.l.
Three phase
230-400-440 Volt / 50-60 Hz
4 Hp 2 poles
IP 54
11.4 - 6.6 A
MANUAL PULL START
169 ml.
P g .
| 4