52932 Write purchased model number here. Escriba aquí el número del modelo comprado. Inscrivez le numéro de modèle ici. T E FLO N • To READ ALL the instructions completely T E FLO N before beginning. • To READ ALL warnings, care, and maintenance information.
Page 2
1/2" (12.70mm) IPS 1/2 po (12.70mm) IPS Faucet Installation Supply Line Connections Make connections to water lines: Use 1/2" IPS faucet connec- Position faucet (1) with single or three hole escutcheon (2) and baseplate tions (1), or use coupling nuts (3) (not supplied) with 3/8" O.D. or gasket (3) on sink.
Page 3
Step 3b Step Step 3c Apply silicone to underside of flange (1). Insert Remove stopper (1) and flange (2). Remove pivot nut (1). Install horizontal rod body (2) into sink. Screw flange (1) into body (2). (2) and stopper (3) as removable (4) or Screw nut (1) all the way down.
Page 4
3/32" (2.38mm) Maintenance If faucet leaks from under handle: Remove handle and ensure bonnet nut (1) is tight. If leak persists–SHUT OFF WATER SUPPLIES. Replace valve cartridge (2) RP50261. If faucet leaks from spout outlet: SHUT OFF WATER SUPPLIES. Replace valve cartridge (2) RP50261. If faucet exhibits very low flow: Remove and clean aerator (3).
Page 5
RP51731▲ Handle Kit Juego de herrajes de la Manija Manette en kit RP51735 Bonnet Nut Bonete Tapón RP51736 RP51732▲ Chapeau Stem Adapter Lift Rod Assembly Adaptador para Espigas (Non Riser Model Only) Rallonge de tige RP50261 Barra de Alzar Valve Cartridge Tige de Manoeuvre Válvula de Cartucho Cartouche...
Page 6
MAKE ANY OTHER WARRANTY OF ANY KIND, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY. Delta will replace, FREE OF CHARGE, during the warranty period, any part or finish that proves defective in material and/or workmanship under normal installation, use & service. Replacement This warranty excludes all industrial, commercial &...