6. Electrical work
Function table
Select unit number "Grp."
Mode
Power failure automatic recovery
Indoor temperature detecting
LOSSNAY connectivity
Power voltage
Auto operation mode
Smart Defrost *3
en
Select unit numbers 1 to 4 or "All"
Mode
Filter sign
Fan speed
Installed options (high efficiency filter)
Up/down vane setting
Fan speed during the cooling thermostat is OFF
*1 When the power supply returns, the air conditioner will start 3 minutes later.
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
*3 It is available when the indoor unit is connected to any of the particular outdoor units.
10
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Not Supported
Supported (indoor unit is not equipped with outdoor-air intake)
Supported (indoor unit is equipped with outdoor-air intake)
240 V
220 V, 230 V
Single set point (Available 14 °C cooling setting *3)
Dual set point (Not available 14 °C cooling setting *3)
Available
Not Available
Settings
100 Hr
2500 Hr
No filter sign indicator
Silent
Standard
High ceiling
Not supported
Supported
No vanes
Equipped with vanes (vanes angle setup 1)
Equipped with vanes (vanes angle setup 2)
Setting fan speed
Stop
Extra low
Mode no.
Setting no. Initial setting
1
01
*1
2
1
02
2
3
1
03
2
3
1
04
2
1
06
2
1
20
2
Mode no.
Setting no. Initial setting
1
07
2
3
1
08
2
3
1
10
2
1
11
2
3
1
27
2
3
setting
Ο *2
Ο
Ο
Ο
Ο
Ο
setting
Ο
Ο
Ο
Ο
Ο

Publicité