Télécharger Imprimer la page

golmar T1220ML Manuel D'installation page 36

Publicité

Les langues disponibles

Les langues disponibles

POWER SUPPLY INSTALLATION
D
etail of the FA-133 power supply installation and technical features.
3,5 x 25
DIN-7971
The power supply can be installed on a DIN 46277
guide simply pressing it To disassemble the power
supply from the DIN guide, use a plain screwdriver
to lever the flange as shown on the picture
133 power supply uses 3 units over DIN guide.
This device has been exclusively designed to be used on Golmar Kit audio AS-1220 SII. Golmar
will not be responsible of the possible damage caused for an improper use or when used for
other purposes than the specified. Install the power supply according to your country rules.
IMPORTANT: Replace the protection cover once the input terminals have been wired.
LOCK RELEASE INSTALLATION
L
ock release installation.
If the lock release will be installed in a metal door,
use a Ø3,5mm. drill and tap the hole In case of
wood door, use a Ø3mm. drill
IMPORTANT:
The lock release must be 12V direct current, (see page 39).
Optionally lock release 12Vac with TF104 transformer and SAR-12/24 relay (see page 40).
The power supply must be installed in a dry and protected
3,5 x 25
DIN-7971
To install the power supply directly on the wall, drill two
holes of Ø6mm. and insert the wallplugs Fix the
transformer with the specified screws
.
Technical features
Input
Power
Output
Working temperature
Dimensions
Weight
.
place It's recommended to protect the power supply
.
by using a thermo-magnetic circuit breaker
. The FA-
DIN 46277
230 Vac / 50 Hz
18 Vdc 0,5A
-10ºC ~ + 35ºC
54(W) x 83(H) x 58(D) mm.
.
.
.
.
9 VA
400 gr.
3,5 x 25
DIN-7972
M 4 x 8
DIN-963
35

Publicité

loading

Ce manuel est également adapté pour:

As-1220 sii