If you notice any malfunction, refer to the checklist below to identify the problem and its possible solutions. If the problem still persists, please
contact the after-sales service.
Equipment does not run and the display does not work
Equipment does not run but the display works
Equipment is not cold enough
Equipment is too cold
Equipment runs continuously
Equipment starts and stops frequently
MNS00058.01
PRT
Instruction Manual
Symptom
Make sure the plug is inserted into the socket
Check for a blown fuse or tripped circuit breaker
Test the power outlet for current
Inspect the electrical cord for damage
Remove any extension cord
Check the temperature setpoint
Assure that there is enough air flow inside the equipment
Clean the condenser coils
Check the temperature setpoint
Assure that there is enough air flow inside the equipment
Check for airflow restrictions in vents
Clean the condenser coils
Clean the door seals
Check for a clogged drain pipe
Check the temperature setpoint
Clean the condenser coils
Clean the door seals
Clean the condenser coils