With the right adjusting dial:
(1)
TIG process - Pulse frequency
(2)
TIG ColdWire - Wire speed
Wire speed vD in m/min or ipm
(3)
TIG DynamicWire - Wire speed correction
For fine adjustment of the wire speed with TIG DynamicWire.
The correction value indicates how quickly the welding wire re-enters the
weld pool after the short circuit is broken.
(4)
Stick / CEL - Arc-force dynamic
To obtain optimum welding results, it will sometimes be necessary to ad-
just the arc-force dynamic.
0 ... soft and low-spatter arc
100 ... harder and more stable arc
How it works:
At the instant of droplet transfer or in the event of a short circuit, there is
a momentary rise in amperage. In order to obtain a stable arc, the welding
current is temporarily increased. If the rod electrode threatens to sink in-
to the weld pool, this measure prevents the weld pool solidifying, as well
as preventing more prolonged short circuiting of the arc. This largely pre-
vents the rod electrode from sticking.