W orking logic
"Step-by-Step" logic (Dip 1 = OFF Dip 2 = ON)
A Start control puts into motion, a following control stops the motion, a further Start control reverses the motion (direction reverse).
"Automatic closing" (Dip 1 = ON Dip 2 = ON)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied during the pause interrupts work
cycle and the gate doesn't close automatically. Photocell intervention during pause time reloads it, extending the period before automatic closing.
"Condominium" logic (Dip 1 = not influent Dip 2 = OFF Dip 3 = not influent)
When the gate has reached opening it will automatically close after the set Pause time. A Start control supplied while opening is not influent.
A Start control supplied while closing provokes the stop and gear reverse after approx. 1,5 sec.. A Start control or Photocell intervention during
pause time reloads it, extending the period before automatic closing.
WARNING: after each modification of the working logic, switch the control unit off and on again to make the change active.
"Immediate closing" (DP3=ON
In opening phase and during pause time, after having passed the Photocell, it determines the stop and, after 1,5 sec., gate closing.
Programming
Learning of remote controls
To enter a Start code, press the P1 key once. To enter a Pedestrian start code, press the P1 key twice. To enter a Courtesy light code, press the P1
key three times. Each time the P1 key is pressed, the DL1 led emits a short flash. After 3 seconds from the last pressure of P1, the DL1 led turns on
with a steady light. Then press the key to be memorized on the remote control. The DL1 led will switch off, indicating that the code has been
memorized. If the code is not recognized, the DL1 led stays on for 10 sec., after which it will automatically switch off .
Erasing of all memorized codes
To delete all the stored codes, keep the P1 key pressed for approx. 10 sec. until the DL1 led turns off.
Setting of pause time
To set the pause time, press the P2 key once. DL1 led emits a short flash and, after 3 sec., turns on with a steady light. Let pass the time
corresponding to the desired time and press again the key P2.
Programming of work time
Rotate the RV1 trimmer to the maximum clockwise. Make sure the gate is completely closed. Press button P3 for approx. 3 sec. until DL1 led
turns on with steady light. Then the gate opens at reduced speed until reaching the opening limit switch. The gate stops and, after 1 sec., closes
at normal speed until reaching the closing limit switch. DL1 led switches off signalling the programming end. The program automatically
computes the point of slowing down start (1/8 of stroke). To modify it, while programming press the key P3 in the wished point during closing step.
Technical data
Card dimensions and weight: 103 x 138 x 45 mm – 0,46 Kg
Card power supply: 230 Vac +/- 10%
Stand-by power consumption: approx. 1 W
Operating temperature range: 0 to + 60 °C
Single-phase motor power supply: 230 Vac 1 HP max.
Blinker power supply: 230 Vac 40 W max.
Courtesy light power supply: 230 Vac 100 W max.
Electric lock power supply: 12 Vac 15 W max.
Accessories power supply: 24 Vac 3 W max.
Pause time regulation: 1 to 300 sec.
DECLARATION OF CONFORMITY
Device description: Electronic board controlling a 230 Vac single-phase asynchronous motor destined to sliding gate automation.
Model:
CTR310
Applied rules:
EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1
Test laboratory:
NEMKO SPA
The manufacturer declares that above mentioned products comply with rules required by European directives 2004/108/EC and 2006/95/EC.
Date: 15-07-2020
CONNECTIONS
DP2=ON)
230V
F1
J5
J3
1
2
3
1
2
3
4
5
6
1
2
3
F2
RV1
DL1
DP1
DL3 DL4 DL5
DL6 DL2 DL7
4
5
6
7
8
9 10 11 12 13 J4
24V