追加資料
VISCA RS-232 制御コマンドテーブル
Command Set
IF_Clear
CommandCancel
CAM_Power
CAM_Zoom
CAM_Focus
CAM_AFMode
CAM_WB
CAM_RGain
Command
Command Packet
Broadcast
88 01 00 01 FF
--
8x 2p FF
On
8x 01 04 00 02 FF
Off
8x 01 04 00 03 FF
Stop
8x 01 04 07 00 FF
Tele(Standard)
8x 01 04 07 02 FF
Wide(Standard)
8x 01 04 07 03 FF
Tele(Variable)
8x 01 04 07 2p FF
Wide(Variable)
8x 01 04 07 3p FF
Direct
8x 01 04 47 0p 0q 0r 0s
FF
Stop
8x 01 04 08 00 FF
Far (Standard)
8x 01 04 08 02 FF
Near (Standard)
8x 01 04 08 03 FF
Far (Variable)
8x 01 04 08 2p FF
Near (Variable)
8x 01 04 08 3p FF
Auto Focus
8x 01 04 38 02 FF
Manual Focus
8x 01 04 38 03 FF
Auto/Manual
8x 01 04 38 10 FF
One Push
8x 01 04 18 01 FF
Direct
8x 01 04 48 0p 0q 0r 0s
FF
Near Limit
8x 01 04 28 0p 0q 0r 0s
FF
Normal AF
8x 01 04 57 00 FF
Zoom Trigger AF
8x 01 04 57 02 FF
Auto
8x 01 04 35 00 FF
ATW
8x 01 04 35 04 FF
Indoor
8x 01 04 35 01 FF
Outdoor
8x 01 04 35 02 FF
One Push WB
8x 01 04 35 03 FF
Manual
8x 01 04 35 05 FF
One Push
8x 01 04 10 05 FF
Trigger
Reset
8x 01 04 03 00 FF
Comments
I/F Clear (Clear Visca connection &
command buffer queue)
p: Socket No. (=1or2)
Power OFF to Standby mode
Power ON supported in Standby mode only
Zoom Control
p=0 (Low) to 7 (High)
pqrs: Zoom Position.
MD120UI: 0x00F0 (x1) ~ 0x5370 (x20)
Focus Control
Each 'Far/Near' needs a 'stop'
p=0 (Low) to 7 (High)
AF ON/OFF
pqrs: Focus Position,
MD120UI: 0x0000(wide) ~ 0x4000(tele)
pqrs: Focus Near Limit Position
0001: 0.3m
0002: 1m
0003: 1.5m
0004: 2m
0005: 3m
0006: 6m
0007: 10m
Continuous AF ON
Continuous AF OFF, only trigger AF after
PTZ done
Normal Auto
One Push WB mode
Manual Control mode
One Push WB Trigger
Return to 80 (128) value
36