6.3.3. Adjustment of product - manual block
(MH42 / MP42)
Adjust product for the manual block by using a limit-
ing nozzle located in the suction nipple of the non-
return valve (image 110009231).
•
Remove the unit cover.
•
Replace the nozzle with a smaller or larger one
to adjust concentration. Refer to the table for
guidance.
6.3.4. Changing air / foam on 1 or 2 products.
(MH42 / MP42)
Nozzle colour
Light blue
Turquios
Yellow
Orange
Green
Black
Beige
Blå
White
Red
110009231
180°
1
→
Concentration by 20 Bar
/290PSI
0.64%
1.07%
1.79%
2.36%
3.15%
4.26%
5.05 %
6,12%
7.00%
7.35%
2
110009474