Stromlaufpläne / Circuit Diagrams / Schémas électriques
3.3 Legende zum Stromlaufplan Wärmepumpenmanager Heizen/Kühlen /
Heat Pump Manager Heating and Cooling: Circuit Diagram Legend /
Légende du schéma électrique du gestionnaire de pompe à chaleur
chauffage et refroidissement
A1
Brücke EVS (EVU-Sperreingang) muss
bei fehlendem EVU-Sperrschütz
eingelegt werden (Brücke offen = WP
aus)
A2
Brücke SPR (Sperreingang
konfigurierbar)
A4
Brücke (Störung Verdichter)
B2*
Pressostat Niederdruck Sole
B3*
Thermostat Warmwasser
B4*
Thermostat Schwimmbadwasser
E9*
Elektr. Tauchheizkörper Warmwasser
E10*
2. Wärmeerzeuger (Heizkessel oder
Tauchheizkörper)
F1
Steuersicherung Standardregler
F2
Lastsicherung für Steckklemmen J12 u.
J13 (N1) / J12 (N2) / Trafo 5x20/4,0ATr
F4
Lastsicherung für Steckklemmen
J15 bis J18 5x20/4,0ATr
H5*
Leuchte Störfernanzeige
Steckklemmen N1 (Heizregler)
J1
Anschluss Stromversorgung der
Regeleinheit (24VAC / 50Hz)
J2
Anschluss für die Fühler R1, R2, R3
J3
Eingang für R7 und R9 über
Steuerleitung-Steckverbinder X4
J4
Analogausgänge werden noch nicht
genutzt
J5
Anschluss für Warmwasserthermostat,
Schwimmbadthermostat und EVU-
Sperrfunktion
J6
Anschluss für die Fühler R5, R8
J7
Anschluss für Alarmmeldung
„Niederdruck Sole"
J8
Ein-, Ausgänge 24VAC zur Steuerung
der WP
J9
Steckdose wird noch nicht genutzt
J10
Steckdose (6pol.) für den Anschluss von
N10
J11
Anschluss für pLAN
J12
Ausgänge für Verdichter und Ventilator
J13
230VAC - Ausgänge für die Ansteuerung
... J18
der Systemkomponenten (Pumpen,
Mischer, Tauchheizkörper, 2.
Wärmeerzeuger)
Steckklemmen N2 (Kühlregler)
J1
Anschluss Stromversorgung der
Regeleinheit (24VAC / 50Hz)
J2
Analogeingänge für Feuchtesensoren
der Raumstationen N3/N4
J3
Analogeingänge für
Temperatursensoren der Raumstationen
N3/N4
J4
Analogausgänge werden noch nicht
genutzt
J5
Digitaleingang (24VAC/DC)
Kondensationsdruck-Pressostat
The utility bridge (utility disable
contactor) must be inserted if there is no
utility blocking contactor (bridge open =
HP off)
SPR bridge (configurable disable
contactor)
Bridge (compressor fault)
Low-pressure brine controller
Hot water thermostat
Swimming pool water thermostat
Electric immersion heater hot water
Heat generator 2 (boiler or immersion
heater)
Control fuse for standard controller
Load fuse for plug-in terminals J12 and
J13 (N1) / J12 (N2) / Transforme
5x20/4.0 A slow-acting
Load fuse for plug-in terminals
J15 to J18 5x20/4.0 A slow-acting
Remote fault indicator lamp
Plug-in terminals N1 (heating controller)
Control unit power supply connection (24
V AC / 50 Hz)
Connection for the sensors R1, R2, R3
Input for R7 and R9 via control line plug
connector X4
Analogue outputs are not used
Connection for hot water thermostat,
swimming pool thermostat and utility
block function
Connection for the sensors R5, R8
Connection for "low-pressure brine"
alarm message
24 V AC input and outputs for controlling
the HP
Socket not used
Socket (6-pole) for connection of N10
Connection for pLAN
Outputs for compressor and ventilator
230 V AC outputs for the control of
system components (pumps, mixer,
immersion heater, heat generator 2)
Plug-in terminals N2 (cooling controller)
Control unit power supply connection (24
V AC / 50 Hz)
Analogue inputs for N3/N4 room station
humidity sensors
Analogue inputs for N3/N4 room station
temperature sensors
Analogue outputs are not used
Digital input (24 V AC/DC) for the
condensation pressure controller
Pont EVS (entrée de blocage EVU) à
insérer en cas d'absence de contacteur
de blocage société électricité (pont
ouvert = PAC arrêt)
Pont SPR (entrée de coupure
configurable)
Pont (panne compresseur)
Pressostat eau glycolée basse pression
Thermostat eau chaude
Thermostat eau de piscine
Thermoplongeur élect. eau chaude
2. générateur de chaleur (chaudière ou
cartouche chauffante)
Fusible de commande régulateur
standard
Fusible pour bornes enfichables J12 et
J13 (N1) / J12 (N2) / Transfo
5x20/4,0A action retardée
Fusible pour bornes enfichables
J15 à J18 5x20/4,0 action retardée
Témoin de télédétection de pannes
Bornes enfichables N1 (régulateur de
chauffage)
Connexion pour l'alimentation en courant
de l'unité de régulation (24 V AC / 50 Hz)
Connexion pour les sondes R1, R2, R3
Entrée pour R7 et R9 via le connecteur
X4 de la ligne de commande
Sorties analogiques libres
Raccordement pour thermostat eau
chaude, eau de piscine et fonction de
blocage soc. élect.
Connexion pour les sondes R5, R8
Connexion du signal d´alarme « Basse
pression eau glycolée »
Entrée/sortie 24 V AC pour commande
de PAC
Prise libre
Prise (6 pôles) pour le raccordement de
N10
Connexion pour pLAN
Sorties pour compresseur et ventilateur
230 V AC - sorties de commande des
composants du système (pompe,
mélangeur, thermoplongeur, 2e
générateur de chaleur)
Bornes enfichables N2 (régulateur froid)
Connexion pour l'alimentation en courant
de l'unité de régulation (24 V AC / 50 Hz)
Entrées analogiques des capteurs
d'humidité des stations N3/N4
Entrées analogiques des capteurs
d'humidité des stations N3/N4
Sorties analogiques libres
Entrée TOR (24 V AC/DC) pressostat
pression condensation
3.3
A-XI

Publicité

loading

Ce manuel est également adapté pour:

Wpm 2006 rWpm 2007 plusWpm 2007 r