Installation safety specification
Table 1 AP10 installation safety specification
Property
Operating environment
Use in wet locations
Operating temperature
Storage temperature
Operating humidity
Operating altitude
Pollution degree
IP rating
Supply voltage using dedicated power supply
connector
PoE power class
Power consumption
Frequency band
More information
For more information on AP10 Access Point, see AP10 User Guide (M211860EN) available at
www.vaisala.com/ap10.
14
Specification
Indoor use
No
−20 ... +60 °C (−4 ... +140 °F)
−20 ... +60 °C (−4 ... +140 °F)
0 ... 90 %RH, non-condensing
Max. 2000 m (6500 ft)
2
IP30: Protected against solid foreign objects of
2.5 mm Ø and greater
10 ... 30 V DC
Class 0
Max. 13 W
See type label on device
M211821EN-F