G
B
ROLLING SHUTTER WITH LENGHT SHAFT OVER 4 m
In this case we suggest to mount 2 JOLLY ONE on the same shaft at the shutter extrimities.
It is necessary to eliminate the limit switch of one of the 2 JOLLY ONE and connect in parallel
the two motors.
JOLLY ONE without limit switches
=
IMPORTANT
3 wires cable to connect the two operators
IMPORTANT!
When mounted with engine on the left all the operations are inverted and limit
switch F1 becomes F2
1 - Cam for end travel
2 - Screw for blockage of the limit switches
F1- Screw for regulation of limit switch which stop the upward movement
F2- Screw four regulation of limit switch which stop the downward movement
For the regulation of the electrical limit switches tighten the two blue screw and unscrew or
tighten the wheels F1 and F2.
To mantain the desired position of the switches you must block the two screws when the
regulation is completed.
ATTENTION:
Avoid all the manouvres of the motor really not necessary during
the regulation. Many manouvres at the same time cause the
intervention of the thermal sensor.
Short travel => Tighten F1
ADJUSTMENT OF THE LIMIT SWITCH WHICH STOPS THE DOWNWARD MOVEMENT
Ground
ADJUSTMENT OF THE LIMIT SWITCH WHICH STOPS THE UPWARD MOVEMENT
Short travel => Unscrew
F2
IMPORTANT: Before fixing the two pulleis to the shutter laminate (4), verify that the sense of
rotation of the 2 JOLLY ONE is the same.
SPRINGS
Ground
Long travel => Unscrew F1
Long travel => Tighten F2
24
JOLLY ONE with limit switches
=
IMPORTANT
Ground
Correct adjustment
Tighten the 2 blocking screw
Correct adjustment
Tighten the 2 blocking screw
4
5
6
7