Close the machine.
Connect the machine to power supply and turn the machine on. Check if the machine
shows « FLO » when the filtration pump is stopped and if it starts up a few seconds after FLO
disappeared on the display when the filtration pump is working.
If not, repeat the precedent setting procedure in the right order, till the settings is
correct.
Utilization
Water connection
After having connected the heat pump to the pool water circuit system trough a suitable by-
pass and having made the electrical connections by a qualified engineer, please verify the
following points:
• Appliance is in a horizontal position and on a solid ground.
• Water circuit is primed (full of water): no air inside the tubes or the heat pump tank.
• Water circuit is well connected (no leaks and no chance of injury due to badly fitted
hydraulic couplings).
• Electrical circuit is well connected (all cables tightened correctly at terminals and
intermediate circuit breaker), insulated and earthed correctly.
• The installation requirements described previously are strictly adhered to.
• Ambient temperature is between : + 5 and + 35° C
• Water temperature is between 15 and 30° C (50° F and 86° F).
• You can then start up your machine. Follow the instructions below in the given order each
time you start up the pool heat pump, especially at the beginning of the swim season:
• Open the three by-pass valves and then half close the settings valve
Unscrew it (1/2 turn).
By-pass diagram
- 38 -