Safety Instructions
Battery
The battery must be recharged properly after use of the scale without mains power.
Normally; charge for 1,2 hours for each using 1 hour.
If it is not used for longer time, then charge it continuously at least for 24 hours. Otherwise it will cause damage to battery.
Before you begin to charge battery, please turn off the scale firstly.
Water/temperature
Protect your scale from heavy raining, water flooding and also from direct sunlight and high temperatures (above 50 degrees), this scale is not
water-proof.
Protect it from the constant humidity, don't install near humidifier.
Magnetic field
Don't install your scale near strong magnetic field it may damage delicate parts of your scale.
Repair/maintenance
Don't try to open the scale by yourself or by unauthorized technical person. This may damage the scale permanently. Always contact your nearest dealer/
service station for emergency repairs.
Technical Data
Model
Voltage/Frequency
Weighing capacity
Subdivision
Platform dimensions
Other features
* This product is intended for laboratory use only.
* The manufacturer reserves the right to make minor changes to product design and technical specifications without prior notice unless these changes significantly affect the performance and safety of the
products. The parts described / illustrated in the pages of the manual that you hold in your hands may also concern other models of the manufacturer's product line with similar features and may not be
included in the product you just acquired.
* To ensure the safety and reliability of the product and the warranty validity, all repair, inspection, repair or replacement work, including maintenance and special adjustments, must only be carried out by
technicians of the authorized service department of the manufacturer.
* Always use the product with the supplied equipment. Operation of the product with non-provided equipment may cause malfunctions or even serious injury or death. The manufacturer and the importer
shall not be liable for injuries and damages resulting from the use of non-conforming equipment.
Description of main parts and functions
Key description
ZERO: the zero key zeroes the scale.
TARE: the tare key subtracts tare values and changes the weighing function from gross mode to net mode.
M: the store key used to store data in your scale.
M+: add key will store and accumulate the value of weight and amount.
M1-M6: Stores unit price value at 6 different locations.
C: The C key is used for cancelling the memorised data.
0-9: the number keys are used for setting unit price data.
DECIMAL POINT: is used for setting the decimal position of unit price.
Display indicators
1. Tare indicator: the tare light is located on the left side below the weight window.
2. Zero indicator: the zero light is located on the right side below the weight window.
3. Ac power indicator: AC power led is located below the total price window.
Operating instructions
General instructions
1. When battery goes low, it is the time to charge the battery with the power line.
2. Before starting using the scale, please check if the scale is in the smooth level, if not, please make adjustment.
Zero the scale
When there is nothing on the scale but reading is not zero, press the zero key to turn on the zero indicator.
Weighing
Ensure that scale is in zero position and zero indicator is glowing, place an item for weighing on the pan, the weight of the item will be showed on the weight
window.
Tare
Put container on the platter, once the weight reading is stable, press the tare key, the tare indicator will be on and the container;s weight will be deducted.
When it is time to clear the tare, take off the container, and press tare key again.
2
DS1500
220V/50-60 Hz
150 kg
50 g
30x40 cm
Rechargeable, foldable
WWW.NIKOLAOUTOOLS.GR
DS3000
220V/50-60 Hz
300 kg
50 g
40x50 cm
Rechargeable, foldable
DS5000
220V/50-60 Hz
500 kg
200 g
45x60 cm
Rechargeable, foldable