Installing the Lamps
• Confirm that power is still disconnected from fixture.
• Make sure fixture is properly grounded.
• Follow STEP 1 for single lamp application or STEPS 2 and 3 for multiple lamp application, based on the number of
lamps in the fixture.
Single Lamp
STEP 1: From AC wires, connect line (L) to Side A lampholder and neutral N(L1) to Side B lampholder. If only one lamp
is being installed, proceed to STEP 4.
Shunted Lampholders
120-277V
Multiple Lamps
STEP 2: Follow the step above for single lamp connection to connect the first lamp.
STEP 3: Connect the terminals from the first lamp to the matching terminals on the lampholder of the second lamp with
line and neutral wires as shown below. Continue daisy-chain connection for each additional lamp.
Shunted Lampholders
120-277V
STEP 4: Complete all electrical connections with appropriate connectors/wire nuts as needed, per all local and national
electrical codes. NOTE: There should not be any exposed wires from sockets left unconnected.
STEP 5: Reinstall wiring compartment cover.
STEP 6: Install all of the SATCO tubes. Install LED tubes so that the LEDs are pointed in the proper direction for illumination,
and install any lens or diffuser as applicable.
STEP 7: Apply power to fixture and check for illumination.
© Copyright 2022 Satco Products, Inc. 3/22 v4.0