FEATURES
• c-UL-us classified and recognized
• Full glass housing: No aging, yellowing, bending
APPLICATIONS
Widely used in residential buildings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc.
for energy saving illumination.
Single Ended
SINGLE-ENDED WIRING INSTALLATION
Removing Existing Fluorescent System
1. Disconnect power from fixture.
2. Remove fluorescent lamp(s).
3. Remove lens and wiring compartment, if applicable.
4. Cut all wires connected to the ballast as shown below and remove ballast.
5. Identify what type of lampholders are in fixture. Single-Ended wiring installation of SATCO tubes requires
non-shunted G13 lampholders.
6. If applicable, replace lampholders with non-shunted lampholders.
Typical Ballast Configurations
A
CAUTION: Use only non-shunted lamp holders for Single-Ended wiring installations.
Do not perform Single-Ended wiring installation of product in a fixture with shunted lampholders (found in all fixtures using
instant start ballasts, Figure 2). If the existing lampholders are shunted, and Single-Ended wiring is desired, remove and
replace them with non-shunted lampholders (or remove the external shunt if applicable). make new connections directly to
lampholder terminals as shown in Figure 1 below.
Typical Non-Shunted Lampholder
Figure 1
© Copyright 2022 Satco Products, Inc. 3/22 v4.0
(NOTE: [ x ] Indicates where to cut existing wiring.)
B
Figure 2