A grounded 3 prong electrical outlet should be placed within
4" (10.2 cm) of the right side cabinets or end panel. See
"Electrical Requirements"
for more information.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. If the water shutoff valve is not in the cabinets, the
plumbing for the water line can come through the floor or the
back wall. See "Water Supply Requirements"
for more
information.
0
0
11oo,,-9o,,
! !(2031229
cm)
!!
;31/2 .. (212.1 cm) min.
043/4'. (215 cm) max.
to bottom of solid soffit
77"
(196
cm)
A
Width
(see chart following)
6"
15.2 cm_,
÷16.
72
cm) '
!
_,152
cm
_-_'_ 6" -1"
24"
(60.96 cm) min.
Model
Width A (as shown above)
36
351/2'' (90.2 cm) to 353/4 '' (90.8 cm)
42
411/2" (105.4 cm) to 413/4" (106.1 cm)
48
471/2'' (120.7 cm) to 473/4 '' (121.3 cm)
NOTE: Flooring under refrigerator must be at same level as
the room. Face of cabinetry must be plumb.
Electdcam Shock Hazard
Pmug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow
these instructions
can resumt in death,
fire, or electdcam shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical
connection.
Recommended
Grounding Method
A 115 Volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended
that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT:
If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred,
and if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect
power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.