2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Fitting lamp:
OMNILUX PAR-30 240V E27 18 LED
OMNILUX PAR-30 ES 230V/11W E27
GE 32481 PAR-30 240V/100W spot 2500h
OMNILUX PAR-30 240V/100W E27 spot
GE 32482 PAR-30 240V/100W flood 2500h
OMNILUX PAR-30 240V/100W E27 flood
Maximum ambient temperature t
Maximum housing temperature t
Minimum distance:
Please note: Every information is subject to change without prior notice. 24.08.2005 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
:
a
:
B
max. 230 V AC, 50-60 Hz ~
max. 100 W
225 x 165 x 240 mm
0.5 kg
No.:
88040505
88040605
88042000
88042005
88042100
88042105
45° C
120° C
0.5 m
18/32
42103520_V_1_1.DOC