Les langues disponibles

Cable-cross-section
The cable-cross-section of all used cables should be at minimum: 0.2mm
Example:
10A current will require minimum cable-cross-section of: 10A x 0.2mm
The cable-cross-section is for 100% copper wire and does not include thickness of the cable sheath.
Device
Max. Input Current
PSI200
PSI400
Setting-up the inverter
To set up the inverter, use the appropriate cables to
• connect the positive pole (usually marked with + or coloured in red) of the battery and the positive
pole (M; coloured in red) of the inverter and
• connect the negative pole (usually marked with - or coloured in black) of the battery and the negative
pole (P; coloured in black) of the inverter and
Ensure to clamp all cables securely.
The Inverter is now ready to use : Set the position of the main switch to I to power on the device. Please
notice the device functions described in chapter "TECHNICAL DESCRIPTION"
NOTE: You can operate the inverter with your vehicle´s engine running or switched off. However, it is
recommended to switch off the inverter while starting the engine.
USB port
Connect the USB external appliance to the USB port and switch it on. The USB port on the power inverter
provides a power supply of 5V DC for external USB devices.
The USB port on the power inverter is not designed for transferring data. Do not connect
memory sticks, MP3 player or similar data storage external appliances. Do not connect
any data transfer cable to the USB port.
20 A
40 A
2
/A
2
2
/A = 2.0mm
Recommended minimum
cable cross section
4mm² (~AWG11)
8mm² (~AWG8)
9