1.
When the unit is turned on the alarm will beep 3 times.
LED monitor displays corresponding functions and status.
2.
Press Fan:
Select Quiet (L), normal dehumidification (M) or faster dry (H).
Keep pressing until you have your desired selection.
1. Continuous sets humidity ratio in the room
2. L (Quiet dehumidification) setting.
3. M (Normal dehumidification) setting.
4. H (Faster dry) setting. A humidity ratio can not be set using this
function.
5. LED pilot lamp illuminates the function status.
Press Mode:
Sets the operating mode to Turbo-Eco-Normal-High.
Keep pressing until you have your desired selection.
Dry (TURBO) - Continuous dehumidifying
During the Continuous dehumidifying function(TURBO), the appliance
will operate continuously, extracting humidity from the air. When this
function is selected the appliance will keep working until the water tank
is full disregarding the relative humidity of the area.
Economical function (ECO) - RH 60%
During the econom ical function (ECO), the dehumidifier will operate to
keep the humidity at 60%. When 60% humidity level is reached,
the dehumidifier will stop dehumidifying and the fan will keep
operating. When the humidity of the area rises above 60%, the
dehumidifier will start operating again.
Normal dehumidification (Medium speed - NORMAL) - RH 50%
During the normal dehumidification mode (NORMAL), the dehumidifier
will operate to keep the humidity at 50%. When 50% humidity level is
reached, the dehumidifier will stop dehumidifying and the fan
will keep operating. When the humidity of the area rises above 60%, then
the dehumidifier will start operating again.
Fast dehumidification (High speed - High) - RH 40%
During the fast dehumidification mode (HIGH), the dehumidifier will
operate to keep the humidity at 40 %. When 40% humidity level is
reached, the dehumidifie r will stop dehumidifying and the fan
will keep operating. When the humidity of the area rises above 40%,
the dehumidifier will start operating again.
All manuals and user guides at all-guides.com
11