Danger
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or high-
er breath-safe masks while carrying out
maintenance tasks (such as changing fil-
ters).
Exchanging the flat pleated filter
Open filter door.
Take out the flat folded filter.
Dispose off the used flat-folded filter in
a dust-tight bag according to the statu-
tory provisions.
Remove the dirt that has accumulated
on the pure air side.
Insert new flat-folded filter.
Close the filter door, it must lock into
place.
– The device is fitted with a disposal bag
with locking slide, order no. 340.766 (10
pcs).
– If the disposal bag is full and the mini-
mum volume flow is fallen short of it has
to be replaced.
– At the end of its lifetime the appliance is
to be disposed of according to the stat-
utory provisions.
All manuals and user guides at all-guides.com
Exchanging the paper filter bag/dis-
posal bag
Properly insert the connection socket in
the suction connection.
Push in the connection socket until it
locks into place.
Turn the suction connection with the
connection socket to the right to close it
tightly.
Note
The accurate fit is ensured by means of a
"bayonet connection".
Paper filter bag
Pull out the paper filter bag to the rear
(1).
Lift the locking slide (2) and tightly close
the paper filter bag when removing it
(see label on the filter element packag-
ing).
Dispose of the used filter element in a
dust-tight bag according to the statutory
provisions.
19