testing anD aDjustments
1. turn on the circuit breaker and light switch.
Note: Sensor has a 1
before it will detect motion. When first turned on
wait 1
/
minutes.
1
2
2. Set:
ON-TIME switch to TEST
SENSITIVITY dial to Midway
TEST
5 10 DUSK
MINUTES TO DAWN
3. Walk through the coverage area noting where you
are when the lights turn on. In TEST mode, light
will stay on for 5 seconds after sensing motion and
then turn off.
4. Adjust the SENSITIVITY to increase or decrease
the range as needed. Too much sensitivity may
cause false triggering due to heat sources in the
coverage area (see Adjustment of Coverage Area
or Troubleshooting section).
5. Set the amount of ON-TIME you want the light to
stay on after motion is detected (5 or 10 minutes)
or...
Set the ON-TIME to the DUSK-to-DAWN setting
if you want the light to stay on all night, every
night. The photocell will turn the light off during
the day.
598-1338-03
All manuals and user guides at all-guides.com
/
minute warm up period
1
2
Photocell
–
+
SEN
6 ft.
(1.8 m)
Maximum Range
The sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coverage area.
Motion
Least Sensitive
5
30 ft.
(9.1 m)
Maximum
Coverage Angle*
(Top View)
Motion
Sensor
Most Sensitive
180°