Télécharger Imprimer la page

Urmet 1039/13 Mode D'emploi page 7

Publicité

Les langues disponibles

Les langues disponibles

WiRiNG iNSTRucTioNS WiTh 1039/90 WiRE
Fit the black wire 1039/90 in a RJ45 plug with Urmet logo:
Remove the black insulating sheath by pulling the two sheath breaking threads to facilitate accommodation
of the wire in the flush-mounting box.
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
Sheath black
Sheath grey
Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and
crimp the plug with a specific tool.
§
Make sure that the grey sheath remains inside the plug.
§
This type of connection DOES NOT ensure double insulation.
TEchNicaL SPEciFicaTioNS
PoWER VoLTaGE aND coNSuMPTioN oN TERMiNaLS V+ V-
Power voltage:
Consumption video call @48V:
Consumption stand-by @48V:
Working temperature range:
Relay contact range c, Nc, No:
Maximum switching voltage:
Maximum switching current:
Maximum switching load:
Garage gate relay contact range (SE2):
Maximum switching voltage:
Maximum switching current:
Max. distance from hall button:
Max. distance from open door sensor:
Max. distance from supplementary power supply:
Max. distance from capacitance lock:
DS1039-06B
All manuals and user guides at all-guides.com
Wire
No.
1
2
1
3
4
8
~ 5 mm
1
8
Wire colour
White-Orange
Orange
White-Green
Blue
Plug
1
8
25m with cable cross-section area 0.5mm
50m with cable cross-section area 1.5mm
100m with cable cross-section area 1.5mm
100m with cable cross-section area 1.5mm
Wire
Wire colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
44 – 57Vdc
-10°c ÷ +50°c
40Va 25W
160ma
100ma
30V
3,5a
30V
200ma
2
2
2
2


Publicité

loading