- If you are not sure that your fast refrigerator has been vertically transported, wait
for 12 (twelve) hours before installing it.
- After having filled the chiller bowl with 20 lt. of glycol and water, insert the plug
in an electrical socket (220V).
- Wait for 16 hours before introducing any type of bottle in the corresponding
lodgings, in order to allow Chiller to bring the liquid in the bowl to the temperature of
(–30°/-35°C).
- If you need to move the refrigerator, never incline it.
- If you forget a bottle in the lodging or any other type of container and this should
break, remove the pocket and put everything under water, paying attention to remo-
ve glass pieces or sharp objects that could damage the protection and the user.
- In order to avoid breaking, never put sharp objects in contact with pockets.
- Before connecting the equipment make sure that the data of the technical plate
correspond to the ones of the electrical net.
- For the electrical installation, you should assure an effective earthing plant, as
foreseen by the current norms.
Main technical features
Voltage/frequency: 220V - 50Hz
Nominal input: 380 W
Compressor 1Ph. - 1/3 HP
Cooling times This appliance has an operating temp. of –30/35°C and lower the tempera-
ture of –1,5°C/minute. On below indicative cooling temperature for each type of product
Products
Sparkling wine
White wine
Rosè wine
Red wine
Can of Coke
Glass bottled water
Other glass bottle
Glass Bottled beer
Glass goblet
THIS APPLIANCE IT'S PROVIDED WITH:
PURE GLICOLE (ANTIFREEZE) FOR THE APPLIANCE
ABT3 - 3 x lt 5 tank + 9 bags as spare part
ABT2 - 2 x lt 5 tank + 6 bags as spare part
Glicole has an expiry date of 12 month, it's possible to replace 5 liters of mixture with 5 lt of pure gli-
cole each 12 month. (After 2/3 years it's suggested to replace completely the mixture of the tank for a
good operation)