Make sure that water cooler is disconnected.
1.
Using a screwdriver, remove the 2 screws, located on
each top sides of the cooler. Then lift the lid.
2.
Remove the black cap from the tank.
3.
Fill the tank with water until the stainless steel coils im-
mersive. Put the cap back.
4.
Remove the right side grid using a screwdriver and
connect the agitator pump terminal at back of the cooler.
5.
Insert the drain tube (1).
6.
Connect the tube (2) on water supply and the power ca-
ble (3).
All tubes are located at the cooler back.
7.
Turn on the water supply.
CAUTION :
ration. Verify inside the tank: a ice cover should progressive-
ly form around the stainless steel coils.
However, if the ice cover is unusually thick, immediately lo-
wering the thermostat from 2 or 3 clicks anticlockwise(-).
Then wait that ice cover thinned
WAIT 2H
quethat the cooler starts refrige-
21