Installation Guide
NOTE: If installing into Fire-Rated wall designs, refer to the Fire-Rated installation guide
1. Be sure debris cover & valve-positioning cover (if included) are
properly installed with valve captured.
NOTE:
If combining multiple boxes side-by-side, use a box clip
(item 696-BC, sold separately or included in a kit) to connect boxes
2. If a metal bracket is not provided, screw the box or box set
directly to stud (recommended). If a metal bracket (L-shape or
U-shape) is provided, secure it to box and attach to stud.
The L-bracket (if included) positions connections away from
stud for easier tool access.
NOTE:
If installing between studs, insert a rigid, flat bracket into
top/bottom track of box. Fasten bracket ends to studs.
3. Connect inlet and outlet lines. Make
all connections per ASTM standards.
NOTE:
ServiceBox models having valves
with a drain port include a yellow flag label.
Install with the flag label on the downstream
side (house/dwelling side) of the valve.
4. Be sure valve (if included) is in ON position and test
all connections for leaks.
Replace any defective product.
5. If included, secure Mainblocks
inlet and/or outlet line. Install as close
to the box as possible.
6. Flush the water line, downstream of the valve,
before operation.
7. At finish, remove debris cover and check (again) for leaks. Keep
valve-positioning cover installed if desired. Keep cover in
place for Fire-Rated installations.
Install frame (item 687-1F, sold separately).
8. Enjoy the Peace of Mind from knowing you have installed a
quality product, made from the best materials available.
Supply
Drainage
Support
on
Specialties
... with L-bracket &
valve-positioning cover ...

Publicité

loading

Sommaire des Matières pour Sioux Chief ServiceBox

  • Page 1 3. Connect inlet and outlet lines. Make all connections per ASTM standards. NOTE: ServiceBox models having valves with a drain port include a yellow flag label. Install with the flag label on the downstream side (house/dwelling side) of the valve.
  • Page 2 3. Connectez les lignes d'entrée et de sortie. Faire toutes les connexions selon les normes ASTM. REMARQUE : les modèles ServiceBox équipés de vannes avec un orifice de vidange comprennent une étiquette drapeau jaune. Installer avec l'étiquette du drapeau en aval côté (côté maison/logement) de la vanne.
  • Page 3 Fire-Rated Installation Guide ASTM E814 Note | Nota | Note ServiceBox installations that require a F/T/H (Flame, Las instalaciones de ServiceBox que requieren una Les installations ServiceBox qui nécessitent une Temperature and Hose Stream) rating should be clasificación de F/T/H (llama, temperatura y flujo de classification F/T/H (flamme, température et flux...
  • Page 4 Marcos se venden por separado | Cadres vendus séparément 2 Boxes - Side x Side over stud 2 Cajas - Lado a lado sobre montante 2 Boîtes - côte à côte sur montant ASTM E814 P: 1.800.821.3944 F: 1.800.758.5950 Sioux Chief Manufacturing Company www.siouxchief.com...