OPERATING INSTRUCTIONS
6. When weighing an item that exceeds
the scale's overload or max capacity
(150 Kg/330 LB), the display will show an
"Err" message (Figure 5). To eliminate
the message, remove the item from the
scale and try again, using an item within
the confines of the scale's capacity. If the
scale's max capacity is exceeded for an
extended period of time, there is a risk of
permanent damage to the scale. Promptly
remove the over-capacity item when you
see the scale displays the "Err" message.
NOTE: To accurately weigh an item, place the item in the middle of the scale
platform. This will ensure the most accurate weight reading.
CALIBRATION INSTRUCTIONS
1. To calibrate the scale, press the "MODE" button for 3-5 seconds. The display will
show random digits, "CAL" and then "50.00 Kg" (Figure 6). Place a 50 Kg/110 LB
weight in the middle of the scale platform.
2. Press the "MODE" button again. The display will show "100.00 Kg" (Figure 7).
Place a 100 Kg/242.5 LB" in the middle of the scale platform.
3. Press the "MODE" button again. The display will show "150 Kg" (Figure 8). Place
a 150 Kg/ LB" weight in the middle of the scale platform.
4. Press the "MODE" button again. The display will show "----" (Figure 9). This
indicates that the calibration is finished and the scale will display the time/clock.
Figure 7
Note: If the scale is not stable during the calibration, the display will only show the
calibration weight and the scale will then automatically power off after two minutes
and will display the time/clock.
Figure 8
-6-
Figure 5
Figure 6
Figure 9