Télécharger Imprimer la page

Wolf 814424 Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

DUAL BLOWER INSTALLATION
For blower models 814422 & 814423
1. Mount blowers to ADAPTER PLATE with (8) 10-24 NUTS
(provided).
(8) 10-24 NUTS
2. Use (8) 10-24 HEX NUTS to attach adapter plate / blower
assembly to (8) THREADED STUDS on the HOOD TOP
PLATE.
3. Plug blower POWER CORD into the receptacle inside the
hood. Route wires away from the blower's moving parts. Bundle
wires with wire tie (provided).
All manuals and user guides at all-guides.com
ADAPTER PLATE
(8) 10-24 NUTS
(8) THREADED STUDS
HOOD TOP PLATE
POWER
CORD
SINGLE BLOWER INSTALLATION
For blower models 814419, 814420 & 814421
MOUNTING PLATE
CENTER
PIECE
(4) 10-24 NUTS
(4) 10-24 NUTS
1. Mount blower to MOUNTING PLATE (provided with blower)
with (4) 10-24 NUTS (provided).
2. Remove CENTER PIECE of ADAPTER PLATE.
3. Mount blower / mounting plate assembly to ADAPTER PLATE
using (4) 10-24 NUTS (provided).
(8) 10-24 NUTS
4. Use (8) 10-24 HEX NUTS to attach adapter plate / blower
assembly to (8) THREADED STUDS on HOOD TOP PLATE.
5. Plug blower POWER CORD into receptacle inside of hood.
Route wires away from the blower's moving parts. Bundle
wires with wire tie (provided).
MODEL • 814424
ADAPTER PLATE
(8) THREADED STUDS
HOOD TOP PLATE
POWER
CORD
99044553A
814440A

Publicité