Télécharger Imprimer la page

Argo LILIUM 11 Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive
materials and 50 cm away from walls or other obstructions.
Make sure the water tank is in the correct position.
Connect the power cord to a suitable electric socket (220-240V/50Hz).
Turn the appliance on with ON/OFF on the control panel.
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 32°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens the dehumidifier goes into defrost mode and the defrost LED comes on. The compressor stops, but the
fan continues running.
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification
function may intermit: please don't turn off the switch or pull out the power plug of the dehumidifier.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
The appliance will only start operating if the humidity level in the room is above the set value.
The dehumidifier will continue to operate until the set humidity level has been reached, with the exception of
interruptions caused by a full tank. In this case, empty and reinstall the tank: the dehumidifier will now start running
again.
WARNING:
After each interruption of its operation, at least 3 minutes must pass before the dehumidifier starts up again:
this delay prevents the compressor being damaged.
If, on the other hand, the set humidity percentage is higher than the level currently found in the room, the
dehumidifier will not start.
If you follow the start up instructions but the dehumidifier does not start stops for no reason, make sure the plug and
power cord are in good working order. After doing so, wait for 10 minutes and then restart the appliance.
If the dehumidifier still does not start after 10 minutes, or if either the power cord or plug are damaged, switch off the
appliance and contact an after-sales service centre.
WARNING:
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the
room. The room temperature will therefore tend to increase. This is completely normal.
To turn the dehumidifier off press the ON/OFF button. This shuts off power to the unit.
Unplug the appliance if you do not intend to use it for some time.
The water extracted from the air can be collected in the provided front tank.
When the tank is full, the unit turns off. The FULL TANK led turns on and the unit beeps for about 20 seconds. Empty
the tank. Use two hands to empty the tank.
To switch off the appliance, press the ON/OFF button and wait a few seconds.
1.
Carefully remove the tank using both hands and following the direction of the arrow.
2.
Empty the tank.
3.
Reposition the tank following the direction of the arrow.
N.B.
Do not use the drain hose when you are collecting condensation in the tank, otherwise water can leak out of the hose.
V 06/17
All manuals and user guides at all-guides.com
OPERATING INSTRUCTIONS
APPLIANCE START-UP
OPERATING PRECAUTIONS
TURNING THE DEHUMIDIFIER OFF
HOW TO ELIMINATE CONDENSATE
(1)
(2)
(3)
17

Publicité

loading

Ce manuel est également adapté pour:

Lilium 13