TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensors have a 1
before they will detect motion.When first turned
on, wait 1
NOTE:Meets the ENERGY STAR
with 120 W Max bulbs.
❒ Turn the RANGE control to the mid position (halfway
between MIN and MAX) and the ON-TIME control
to the TEST position.
ON-TIME
10 5 1 TEST
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
per Sensor
Maximum Range
both Sensors
Get user manuals:
See SafeManuals.com
/
minute warm up period
1
2
/
minutes.
1
2
guidelines when used
®
RANGE
ON-TIME
RANGE
MIN
MAX
MIN
10 5 1 TEST
MINUTES
Bottom of Sensor
70 ft.
(21 m)
Maximum
Coverage Angle
per Sensor
Maximum
Coverage Angle
both Sensors
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aim-
ing the sensors down will reduce coverage distance.
The sensors are less sensitive to motion directly towards
them.
Motion
Least Sensitive
❒ For each sensor, loosen the
clamp screw in the sensor ball
joint and gently rotate the sen-
MAX
sor.
❒ Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several times
when motion is detected).Move
the sensor head up, down, or
sideways to change the cover-
age area. Keep the sensor at
least 1" (2.5 cm) away from
the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
180°
on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps
at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . Up to 360° (180° each sensor)
360°
Electrical Load. . . . . . Up to 300 Watt Maximum Tung-
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
4
Motion
Sensor
Most Sensitive
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
sten [Up to 150 Watt maximum
each lamp holder.]
MODE
598-1351-01