Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AMR PULSE W-Mbus- Mode d'emploi / User guide version V1.2
Type
Version
Device type
Frame code
Access number
Status
Signature
Encryption verification
DIF
Index
VIF
(data)
Data
RSSI

4.2. Error codes

Below, an error code table
Code
Bit7
Bit6
Status
Fraud
Reserved
0x00
0
0x04
0
0x32
0
0x92
1
0x8C
1
0x96
1
Bits 0 and 6 are used to check that the product is operating correctly. If one of the bits is enabled, after sales service must be contacted.
Note 1: The switch consistency check is carried out every minute.
Note 2: Fraud detection is verified every 4 seconds. The switch from temporary fraud to permanent fraud will be made after 1 hour of temporary
fraud. The return to a fault free frame will also occur 1 hour after reconnection of the fraud wire.
Description
Product version
Product type
Identifies the frame type
Access number
Status
Fixed marker
Data format
Data value
Meter data
Signal reception level
Bit5
Bit4
Switch
Temp.
0
0
0
0
0
0
0
1
1
0
0
1
0
0
0
0
0
1
0x03 : Gas
0x07 : Water
0x02: Electricity
0x0C : Heat (heat meter)
0x7A : Index frame
Incrementation on the transmission of each new frame
0x00 : NO ERROR (see error code table
0x00 -->
0
: Number of blocks of 16 encrypted bytes
0x00 : no encryption
0x05 : AES128 mode 5 encrypted
0x2F 2F : start of the frame if not encrypted
0x04 : 32 signed bits
0x12 : value expressed in tenths of a dm3 (ie. 0.1 litres)
0x D6 47 00 00 : Read 00 00 47 D6 in hexadecimal, ie
18390 in decimal = 1839 litres (1.839m3)
RSSI (in hexadecimal) of the frame received: RSSI value =
-125 +(x*0.5), ie in this example 6E = 110
RSSI = -125 + (1101*0.5) = -70dBm
Bit3
Bit2
Bit1
Perm.
Low Bat.
Error
0
0
0
0
1
0
0
0
1
0
0
1
1
0
1
0
1
1
Value
Bit0
Description
Reserved
0
No code status
0
Low bat error
0
Config switch error
0
Temporary fraud
0
Permanent fraud
0
Temporary fraud + Low
bat error
Page
42
of 44