Installation distances
C886 / C886G Style
Combustible roof
465
Ø 490
INSTALLATION AGAINST COMBUSTIBLE WALLS
Combustible wall
200
Permitted area for
combustible parts
of the building
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
WHEN INSTALLING TURNTABLE (OPTION) the following
installation distances do not apply.
See the separate turntable installation instructions.
100
400
Combustible wall
500
732
The minimum distance in front of the
stove opening to combustible parts
of the building or interior decoration
must be at least 1,1 m.
The dimension diagrams only show
the minimum permitted installation
distances for the stove. When con-
necting to a steel flue, also note the
safety distance requirements of the
flue. The safety distance between an
uninsulated flue and a combustible
part of the building should be at least
450 mm.
365
A = height from floor to chimney
Ø150
183
B = height from floor to c/c chimney
C = height from floor to air inlet
46
D = height from floor to lower edge
E = minimum height to sloped ceiling
F = height from floor to knockout in
Air inlet Ø67
245
INSTALLATION AGAINST FIREWALLS
750
Fire-retardant wall of
brick or concrete
50
700
Fire-retardant wall of
brick or concrete
200**
432**
connection upwards
connection rear
of hatch
from the centre of the chimney
the pedestal