Installation (continued)
PLACEMENT
Move the assembled unit to its final location. If required, level the unit by adjusting the leveling legs (F). Ensure that no rocking is
exhibited .
SUPPLY LINE
The supply lines, which connect the faucet to the household water system, are
not supplied with this unit . They need to be purchased separately . Follow the
supply line manufacturer's instructions for proper installation .
Maintenance
CARTRIDGE REPLACEMENT
If in the future the ceramic cartridge needs to be replaced:
1 . Turn off the water supply to the faucet (C) .
2 . Take off the plastic water temperature sign by hand, then use the
Hex key to take out the screw and pull out the handle body . The top
lever of the cartridge will be exposed .
3 . Unscrew the cap and rings, making sure not to damage the
threads .
4 . Pull the cartridge out of the faucet body and replace it with a new
35 mm ceramic cartridge .
5 . Replace the rings, then the cap .
6 . Place the handle body on the cartridge . Lock the screw back
onto the handle body and tighten it with the Hex key . Do not over
tighten .
7 . Put the plastic water temperature sign back into the hole, make
sure that red is on the left and blue is on the right .
8 . Slowly open the water feed to the faucet to test .
QL052
Cartridge
Faucet body
10
Water temperature sign
Screw
Cap
Rings
Handle
body