1. Knock out the fresh air intake hole at the top panel
2. Assemble the axial fan, fresh air adapter, filter and dust hose as shown in figure below.
ASSY. FRESH AIR ADAPTER
FILTER FRESH AIR INTAKE
3. Connect the wire to the control box as indicated in the wiring diagram below:
WIRED OR
WIRELESS
REMOTE
CONTROLLER
FA : FRESH AIR
4. The axial fan model are as follow.
a. ebm axial fan.
8556A - pin type.
b. ebm axial fan.
8556N - wire type.
The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruction
to the smooth air flow. Please follow the installation
clearance shown in the figure. Select the coolest possible
place where intake air temperature is not greater than the
outside air temperature (maximum 45°C).
Installation Clearance
Dimension
A
Minimum Distance
300
(mm)
NOTE : If there is any obstacle higher than 2m, or if there
is any obstruction at the upper part of the unit,
please allow more space than the figure indicated
in the above table.